Copper-Nickel 90/10 (CuNi10Fe1Mn / UNS C70600 type) TIG welding rods and MIG spooled wires engineered for marine engineering, shipboard seawater cooling lines, offshore firewater piping and hull cladding.

EN ISO 24373 S Cu 7061 / Matching UNS C70600 (or AWS A5.7 ERCuNi) UNS: UNS C70600 / C70620 Series Werkstoff: 2.0872 (CW352H) GTAW (TIG), GMAW (MIG)
Cupro Nickel 90/10 copper nickel marine welding filler wire
Cupro Nickel 90/10 (CuNi10Fe1Mn) TIG cut-length rods and layer-wound MIG spools.
Copper Nickel Filler Wires

90% Copper / 10% Nickel Welding Consumables for Marine Seawater Piping & Cladding

Cupro Nickel 90/10 Filler Wire (nominal 88% Cu – 10% Ni – 1.4% Fe – 0.8% Mn with titanium deoxidizer) is engineered for welding 90/10 copper-nickel (UNS C70600 / W.Nr. 2.0872 / CW352H) seawater piping, condenser shells, desalination evaporators and boat hulls where welding procedures specify a matching 90/10 deposit composition or where 90/10 wire is used for anti-biofouling weld overlay cladding.

In addition to matching 90/10 composition wire, international marine standards (such as AWS A5.7) also frequently specify 70/30 ERCuNi filler wire for joining 90/10 base metal to provide a cathodic over-matching weld seam. FillerWires supplies both matching 90/10 CuNi filler wire and 70/30 ERCuNi filler wire to meet your exact project WPS.

AWS Classification EN ISO 24373 S Cu 7061 / Matching UNS C70600 (or AWS A5.7 ERCuNi)
EN / ISO Classification EN ISO 24373 S Cu 7061 (CuNi10Fe1MnTi)
UNS / Werkstoff Nr. UNS C70600 / C70620 Series / 2.0872 (CW352H)
Welding Processes GTAW (TIG), GMAW (MIG)

Alloy Identification, Standards & Supply Specifications

Controlled iron (1.0–1.8% Fe) in 90/10 copper-nickel is dissolved in solid solution to provide optimal impingement resistance in flowing seawater up to 3.5 m/s, while titanium deoxidizers ensure sound, porosity-free welds.

Technical Product Specification Summary — Cupro Nickel 90/10 Filler Wire
Product Designation Cupro Nickel 90/10 Filler Wire (TIG Welding Rod / MIG Spooled Wire)
AWS / ASME Classification EN ISO 24373 S Cu 7061 / Matching UNS C70600 (or AWS A5.7 ERCuNi)
EN / ISO Classification EN ISO 24373 S Cu 7061 (CuNi10Fe1MnTi)
UNS Designation & Werkstoff Nr. UNS C70600 / C70620 Series • W.Nr. 2.0872 (CW352H)
Compatible Base Materials Copper-Nickel 90/10 (UNS C70600 / EEMUA 144 / DIN 86019 / CW352H) seamless and welded seawater pipes, fittings, flanges and marine hull plates.
Supported Welding Processes GTAW (TIG), GMAW (MIG)
Shielding Gas Recommendations 100% Argon or Argon + Helium
Available Wire Diameters MIG Spools: 0.8mm (.030"), 0.9mm (.035"), 1.0mm (.040"), 1.2mm (.045"), 1.6mm (1/16")
TIG Cut-Length Rods: 1.2mm, 1.6mm (1/16"), 2.0mm, 2.4mm (3/32"), 3.2mm (1/8"), 4.0mm (5/32") × 914mm (36") / 1000mm
Packaging & Storage TIG Rods: 5 kg / 10 kg moisture-resistant tubular plastic packs in export master cartons.
MIG Wire: 12.5 kg / 15 kg precision layer-wound BS300 / S200 spools sealed in VCI polyethylene film.
Storage: Store in a dry, temperature-controlled indoor store (+10°C to +40°C, <60% RH) in original sealed packaging.

Chemical Composition Specification (EN ISO 24373 S Cu 7061 / Matching UNS C70600 (or AWS A5.7 ERCuNi))

The table below specifies the standard wire chemical composition limits in weight percent (wt.%). Single values represent maximum permissible limits unless stated otherwise:

Chemical Composition Limits — Cupro Nickel 90/10 Filler Wire
Element Verified Specification Limit (wt.%) Metallurgical Function in Weld Metal
Copper (Cu) Remainder (~86 – 88%) Provides high thermal conductivity and anti-biofouling marine resistance
Nickel + Cobalt (Ni+Co) 9.0 – 11.0 Enhances corrosion resistance and strength in seawater
Iron (Fe) 1.0 – 1.8 Critical addition providing impingement and erosion-corrosion resistance
Manganese (Mn) 0.50 – 1.00 Deoxidizer and sulfur binder
Titanium (Ti) 0.15 – 0.50 (Welding Grade) Prevents oxygen/nitrogen porosity in the molten weld pool
Lead (Pb) 0.02 max Strictly restricted to prevent hot cracking
Phosphorus (P) & Sulfur (S) P ≤ 0.020, S ≤ 0.020 Low impurity limits for weld soundness
Carbon (C) 0.05 max Controlled carbon limit for welding grade

Mechanical & Physical Properties

The values below distinguish between minimum AWS/ISO classification requirements for all-weld-metal test assemblies and typical as-welded deposited weld metal benchmarks:

Mechanical & Physical Property Reference — Cupro Nickel 90/10 Filler Wire
Property Value Unit Specification / Reference Basis
Tensile Strength ≥ 275 (Typical: 300 – 340) MPa Typical As-Welded 90/10 Deposit (≥345 MPa with ERCuNi)
Yield Strength (0.2% Offset) ≥ 105 (Typical: 125 – 155) MPa Typical As-Welded GTAW Deposit
Elongation ≥ 30 (Typical: 34) % In 50 mm Gauge Length
Density 8.94 g/cm³ Physical Property Reference
Melting Range 1100 – 1145 °C Physical Property Reference
Technical Verification Statement: Standard limits above reflect published AWS / ASME / EN ISO classification specifications and typical deposited weld metal properties. Actual heat-specific test results depend on wire diameter, batch chemistry and welding procedure parameters. Contact us for confirmed product specifications and available technical documentation.

Corrosion Resistance, Welding Considerations & Industrial Applications

Cupro Nickel 90/10 is the workhorse alloy for offshore platform firewater, seawater cooling and ballast systems (such as EEMUA 144 / 234 piping specifications). When welding 90/10 pipe, ensure thorough degreasing, use pure Argon back-purging for full-penetration GTAW root runs, and avoid weave beads wider than 2.5 times the electrode diameter.

Typical Industrial Applications

  • Offshore oil & gas topside seawater cooling and Deluge firewater piping (EEMUA 144 / UNS C70600)
  • Shipboard engine-room cooling water, bilge, ballast and sanitary seawater lines
  • Multi-Stage Flash (MSF) and MED desalination heat recovery and condenser tubing/waterboxes
  • Aquaculture cages, workboat hulls and offshore wind turbine splash-zone protection
  • Power station steam surface condensers and auxiliary heat exchangers

International Enquiry Destinations

FillerWires welcomes B2B export enquiries for Cupro Nickel 90/10 Filler Wire from EPC contractors, process equipment fabricators, shipyards and distributors across the following priority countries and industrial cities:

International Enquiry Destinations for Cupro Nickel 90/10 Filler Wire
Target Country Relevant Industrial Cities & Ports Typical Regional Sector Demand
United Arab Emirates & Oman Abu Dhabi, Dubai, Sharjah, Fujairah, Muscat, Sohar, Duqm Offshore topside firewater piping, desalination & shipyards
Saudi Arabia, Qatar & Kuwait Dammam, Jubail, Jeddah, Doha, Ras Laffan, Shuwaikh, Shuaiba Offshore platforms, LNG cooling & desalination plants
Bahrain, Singapore & Sri Lanka Manama, Hidd, Jurong, Tuas, Pioneer, Colombo, Trincomalee FPSO conversion, drydock shiprepair & marine piping
Italy, UK, Germany & Norway Genoa, Venice, Trieste, Aberdeen, Southampton, Hamburg, Stavanger Shipbuilding, North Sea offshore & marine condensers
United States, South Africa & Peru Houston, New Orleans, San Diego, Durban, Cape Town, Callao, Ilo Offshore production rigs & commercial/naval vessels

Frequently Asked Questions — Cupro Nickel 90/10 Filler Wire

Technical questions and answers regarding classification, base metal compatibility, welding parameters and procurement for Cupro Nickel 90/10 Filler Wire:

Cupro Nickel 90/10 Filler Wire is classified under EN ISO 24373 S Cu 7061 / Matching UNS C70600 (or AWS A5.7 ERCuNi) and EN ISO 24373 S Cu 7061 (CuNi10Fe1MnTi) (UNS UNS C70600 / C70620 Series, Werkstoff Nr. 2.0872 (CW352H)). Contact us for confirmed product specifications and available technical documentation.

Cupro Nickel 90/10 Filler Wire (EN ISO 24373 S Cu 7061 / Matching UNS C70600 (or AWS A5.7 ERCuNi)) is engineered for welding Copper-Nickel 90/10 (UNS C70600 / EEMUA 144 / DIN 86019 / CW352H) seamless and welded seawater pipes, fittings, flanges and marine hull plates.

Cupro Nickel 90/10 Filler Wire is supplied for GTAW (TIG), GMAW (MIG) as precision layer-wound MIG spools (0.8mm, 0.9mm, 1.0mm, 1.2mm, 1.6mm) and straight cut-length TIG rods (1.2mm, 1.6mm, 2.0mm, 2.4mm, 3.2mm, 4.0mm in 914mm / 36-inch and 1000mm lengths). Recommended shielding gas: 100% Argon or Argon + Helium.

Cupro Nickel 90/10 is the workhorse alloy for offshore platform firewater, seawater cooling and ballast systems (such as EEMUA 144 / 234 piping specifications). When welding 90/10 pipe, ensure thorough degreasing, use pure Argon back-purging for full-penetration GTAW root runs, and avoid weave beads wider than 2.5 times the electrode diameter. Typical applications include: Offshore oil & gas topside seawater cooling and Deluge firewater piping (EEMUA 144 / UNS C70600); Shipboard engine-room cooling water, bilge, ballast and sanitary seawater lines; Multi-Stage Flash (MSF) and MED desalination heat recovery and condenser tubing/waterboxes.

Direct Export & Procurement Desk

International B2B Technical Enquiry & Quotation Request

Submit your alloy grade, AWS/ISO classification, diameter, welding process and delivery destination. Our technical export team in Mumbai responds to enquiries from the Middle East, GCC, USA, UK, Europe, Singapore, Sri Lanka, South Africa, Peru and global markets.

Section A – Contact Information
Section B – Product Requirements
Multiple grades accepted. If unsure of the exact classification, enter “Not sure – Need technical assistance”.
Section C – Quantity Requirements
Section D – Technical and Project Details
To share technical specifications or supporting documents, please email info@fillerwires.com directly.
Direct Email: info@fillerwires.com | Tel/WhatsApp: +91 7045 212 326

Ready to Source Certified Welding Filler Wires for Your Next Project?

Connect with our international export team in Mumbai for technical datasheets, alloy availability, packaging options and competitive CIF/FOB quotations for the Middle East, GCC, USA, UK, Europe and global markets.